Show facility-alarm status. Use the command "show platform" or "show facility-alarm status" to determine status of Fans in the Tray. Show facility-alarm status

 
Use the command "show platform" or "show facility-alarm status" to determine status of Fans in the TrayShow facility-alarm status  10

Verifies the. show facility-alarm status [info | major | minor] Shows information on all alarms that have been triggered. Title: Alarms for the Cisco ISA 3000Forexample,toenableallactionsforthealarminputcontact1,enterthefollowing: alarmfacilityinput-alarm1relay alarmfacilityinput-alarm1syslog alarmfacilityinput-alarm1notifiesshow alarm profile [name] Displays all alarm profiles in the system or a specified profile. Theseverity controlsthebehavioroftheLEDassociatedwiththecontact. You can view these alarms using the show facility alarm status command. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. The following example shows a. alarm facility power-supply notifies. You can connect an external alarm, such as a buzzer or light, to the alarm output interface. Verifying Normal Startup Sequence. For the latest feature information and caveats, see the release notes for your platform and software release. Alarm support is intended to cover a focused subset of router states that are likely to. This bulletin replaces Bulletin 2000-021-BU/EL, Bulletin 2000-019-BU/EL and Bulletin 2003. Configuration Example. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. show facility-alarm. Examples of Alarm Messages. This new centralized module management facility provides a common way to control and monitor all the modules in the system regardless of their type. h = 5*10-10 / 10-8 = 5*10-2 = 0. Bias-Free Language. show facility-alarm status —Displays the alarms status attached to a specific profile. Enter the show facility-alarm status command. In this moment the alarm is only INFO. The following are examples of alarm messages that are sent to the console. For the latest feature information and caveats, see the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. 7. 11. Check for the following o/p: show facility-alarm status GigabitEthernet0/0/0 CRITICAL Physical Port Link Down [1] GigabitEthernet0/0/2 CRITICAL Physical Port Link Down [1] See if you have any ports down or if it says CRITICAL anywhere in the above. Returns to privileged EXEC mode. To view alarms, use the show facility-alarm status command. Verifying Normal Startup Sequence. show facility-alarm status [critical | info | major] Displays generated alarms on. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. The show platform command displays the online status information for router FRUs. When i issue a command "show facility-alarm status" below shows this, when i plugged in a fiber cable no LED and such and i issues the same command the below description still remains. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Monitoring >Properties >Alarm > Facility Alarm Status AlarmportssupportfortheISA3000 9. Note: To clear the the alarm LED, you need to shutdown the ports which are not connected. Sends power supply alarm traps to a syslog server. Finally, clearing the alarms with clear facility-alarm most likely won't work unless the state of the interface(s) has changed either to admin down or up/up because the alarm will just be thrown again in a couple of seconds. You can view the SNMP traps through the SNMP manager. The documentation set for this product strives to use bias-free language. In the event of a Fan failure, the Fan tray status will be displayed as "fail" along with the details of the individual€units which has failed. For the latest feature information and caveats, see the release notes for your platform and software release. 11. The console terminal displays the following error message if you execute. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored but the power supply state remains in OK state as the. The info keyword provides the same output as using no keyword. show facility-alarm relay. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. copy running-config. Displays the switch power status. Monitoring >Properties >Alarm >Facility Alarm Status AlarmportssupportfortheISA3000 9. However, most likely it could be some issue such as failed power supply, etc that will not clear. Send power supply alarm traps to a syslog server. on my router-1, port 0 is active, port 1 is inactive. show facility-alarm status. showf~showipu •showfacility-alarm(3ページ) •showfailover(6ページ) •showfailoverdescriptor(21ページ) •showfailoverexec(22ページ)The following is the output of "show facility-alarm status" CLI command; it displays all alarms currently asserted in the device: R5-mcp-2ru-1#sh facility-alarm status System Totals Critical: 2 Major: 1 Minor: 0 Source Severity Description [Index]. Step 4 . end. Router(config)# logging alarm critical. 2. After system bootup, the PSU state can be viewed with the show platform or show facility-alarm status commands. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Router# show environment alarm-contact ALARM CONTACT 1 Status: not asserted Description: test. Returns to privileged EXEC mode. Enter the show facility-alarm status command at the console. Mark as New;For the latest feature information and caveats, see the release notes for your platform and software release. Managing Alarms via the MIB. The LEDs indicate all system states in the startup sequence. System Totals Critical: 22 Major: 0 Minor: 0. f985. The documentation set for this product strives to use bias-free language. Configuring the Power Supply Alarms. 7. The switch can also monitor the status of the Ethernet ports and generate alarm messages based on the alarms listed in Table 5-2. Description. Use the show facility-alarm status command to determine the current alarm conditions. Step 4 . For the latest feature information and caveats, see the release notes for your platform and software release. ASR903#show platform | in FAN|State Chassis type: ASR-903 Slot Type State Insert time (ago)Insteadofconfiguringonecontact,youcanspecifyanytochangetheseverityforallcontacts. For the latest feature information and caveats, see the release notes for your platform and software release. The info keyword provides the same output as using no keyword. Alarms. ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. No alarm condition exists. •show facility-alarm status [info |major |minor] AlarmsfortheCiscoISA3000 6 AlarmsfortheCiscoISA3000 MonitoringAlarms. Step 9. For the latest feature information and caveats, see the release notes for your platform and software release. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Verifying Normal Startup Sequence. You may be able to also use. Source-----subslot 0/0. For the latest feature information and caveats, see the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. router# show facility-alarm status | inc Temp Temp: Outlet P0/4 Apr 18 2016 13:05:12 INFO. show facility-alarm status GigabitEthernet0/0/0 CRITICAL Physical Port Link Down [1] GigabitEthernet0/0/2 CRITICAL Physical Port Link Down [1] See if you have any ports down or if it says CRITICAL anywhere in the above o/p. Verifying Normal Startup Sequence. Alarms. ASR Facility Alarms. For the latest feature information and caveats, see the release notes for your platform and software release. pemasirid. 10. alarm facility power-supply syslog. Examples. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. ROUTER#show facility-alarm status. However, network administrators can perform onsite. 显示有关已触发输出中继的警报信息。 show facility-alarm status [info | major | minor] 显示所有已触发. Sends power supply alarm traps to a syslog server. Alarms. Router(config)# logging alarm critical. The following example. Use the show facility-alarm status command to determine the current alarm conditions. Router#show alarm Alarm contact 0: Description: External alarm contact on Motherboard Status: Not Asserted Application: Dry Severity: major Trigger: Open Mode: Input Router# Router#show facility-alarm status System Totals Critical: 0 Major: 1 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- External alarm contact Oct 16. Dependingontherequirement,youcanoverridethedefault. show facility-alarm status [info | major | minor] Shows information on all alarms that have been triggered. For the latest feature information and caveats, see the release notes for your platform and software release. show env power . show. See the Cisco 10000 Series ESR Troubleshooting Guide. Displays all global alarm settings on the switch. •major. Send power supply alarm traps to an SNMP server. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. Additionally, you can use the show facility-alarm status command to view the alarms. show facility-alarm status [critical | info | major] Displays generated alarms on. For the latest feature information and caveats, see the release notes for your platform and software release. Source Severity Description [Index] GigabitEthernet0/0/0 INFO Physical Port Administrative State Down [2]. 10. Step 11 copy running-config startup-config (Optional) Saves your entries in the configuration file. To display the alarm status attached to a specfic profile, use the show alarm profile command: Router# show facility-alarm status | inc 0/3/0 t1 0/3/0 Feb 01 2018 19:23:10 CRITICAL Section Receiver has loss of signal [1] Verifying Alarm Profile for Severity Change for T1 or E1 AlarmsHello, I have recently upgraded two ASR1001s to a new IOS-XE version, and the "Major" LED light is on for both of them now. Shows information about the physical status of the input alarm contacts. show redundancy summay give you more information . To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Verifies the. . Use the show facility-alarm status command to display more information about the alarm condition. Verifying Normal Startup Sequence. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Is it possible to disable the critical facility-alarm for the 'interface link-down' status, so the 'stat' led on the device doesn't turn red? (the interface is intended to be no shut, but normally down) #show facility-alarm status System Totals Critical: 1 Major: 0 Minor: 0 Source. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. To clear the the alarm LED, you need to shutdown the ports which are not connected. 8. show alarm settings. Returns to privileged EXEC mode. alarm facility power-supply syslog. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored but the power supply state remains in OK state as the. show redundancy summay give you more information . 7. Step 9. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. If a severity level is issued with the show facility-alarm status command, then only the alarms and events containing the matching severity level are displayed. show alarm settings. show environment alarm-contact. show env power. end. Send power supply alarm traps to a syslog server. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. Additionally, you can use the show facility-alarm status command to view the alarms. show alarm settings. Your software release may not support all the features documented in this chapter. Source. Switch#show facility-alarm status Source Severity Description Relay Time Switch MINOR 34 HSR ring is partially down MAJ Oct 24 2017 10:16:10 ----- Switch# show facility-alarm status Source Severity Description Relay Time Switch MAJOR 33 HSR ring. Source. Router# show facility-alarm status System Totals Critical: 18 Major: 0 Minor:. Critical alarm, this is embedded in the IOS code and cannot be switched off. show facility-alarm status [info | major | minor] This command displays all alarms based on severity specified. copy running-config startup-config•show environment power •show platform hardware slot P <0-5> mcu status •show facility-alarm status •show redundancy •show redundancy line card all •show ip ospf neighbor •show cable modem voice •show cable calls •show cable licenses all •show inventory •show log •show cable rpd •show cable modem summary total •show cable. •major. Alarms. Forexample,toenableallactionsforthealarminputcontact1,enterthefollowing: alarmfacilityinput-alarm1relay alarmfacilityinput-alarm1syslog alarmfacilityinput-alarm1notifiesAlarm Deletion. Network administrators do not need to use show commands to poll devices on a routine basis and can monitor the network remotely. I have attached a show ip int bri & show facility-alarm status since it is more user. After system bootup, the PSU state can be viewed with the show platform or show facility-alarm status commands. The following example shows how to use the show facility-alarm status command to verify if any critical alarm is generated when a module is removed from the system: Device# show facility-alarm status System Totals Critical: 8 Major: 0. show env {all |. Step 11 Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- subslot 0/0 May 18 2016 14:50:49 CRITICAL Active Card Removed OIR Alarm [0] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1] GigabitEthernet0/1/1 May 11 2016 18:53:36. Displays the current major, minor, and critical alarm status, if any, and displays the configuration of the alarm thresholds. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Shows information about the physical status of the input alarm contacts. Checking Status Using show Commands. end. alarm facility power-supply notifies. For the latest feature information and caveats, see the release notes for your platform and software release. 7. Monitoring Syslog Messages for Alarms. Step 5 . To view alarms, use the show facility-alarm status command. Once hardware is installed and operational, use alarms to monitor hardware status on a daily basis. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Examples of Alarm Messages. 9. Verifying Normal Startup Sequence. The following example. Table 9-4 show facility-alarm status Field Descriptions Field Description System Totals Shows the number of alarms in the output display by severity. Verifies the. For the latest feature information and caveats, see the release notes for your platform and software release. Displays all generated alarms for the switch. Theseverity controlsthebehavioroftheLEDassociatedwiththecontact. The following example de-energizes the output relay and clears the alarm state of the output LED: > clear facility. show facility-alarm statusコマンドを使用して、LED. Displaysallthealarmsthathavebeentriggered. Return to privileged EXEC mode. Returns to privileged EXEC mode. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. The documentation set for this product strives to use bias-free language. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. -- ' 'Good body every evening' ' this sentence was once spotted on a logo at the entrance of a Weight Watchers Club ! 0 Helpful Reply. show alarm settings. Severity. Displays the switch power status. Starting from Cisco IOS XE Gibraltar 16. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored but the power supply state remains in OK state as the. Command Purpose Command Purpose 1. For the latest feature information and caveats, see the release notes for your platform and software release. show env {all | power | temperature} Displays the status of environmental facilities on the switch. For the latest feature information and caveats, see the release notes for your platform and software release. Displays all global alarm settings on the switch. The documentation set for this product strives to use bias-free language. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. status. show environment alarm-contact. Go to solution. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. Verifying Normal Startup Sequence. 7(1) AlarmsfortheCiscoISA3000 8 AlarmsfortheCiscoISA3000 HistoryforAlarms. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. show alarm settings. To view the alarms on Cisco ASR 1001 router, use the show facility-alarm status command. ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014. CORE010# show facility-alarm status Source Severity Description Relay Time ! <-----!!!!! And it still says Gi1/1 it is up, but it is unplugged! CORE010# sh int gi1/1 GigabitEthernet1/1 is up, line protocol is up (connected) Hardware is Gigabit Ethernet, address is 34c0. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. show facility-alarm statusコマンドを使用して、LED. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. Title: Alarms for the Cisco ISA 3000Alarm Yellow Off Indicates an alarm condition at OC-12, DS3, or DS1 level. The LEDs indicate all system states in the startup sequence. Use the show facility-alarm status command to display more information about the alarm condition. Table 5-1 Switch Global Status Monitoring Alarms FCS Error Hy. Step 7 . Command or Action Purpose Step 1 enable Example: Router> enable. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. 9. show facility-alarm status. Environmental Monitoring; Fan Failures; Reporting. You cannot establish a. ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. Source Severity Description [Index]----- ----- -----subslot 0/0 CRITICAL Active Card Removed OIR Alarm [0] Is there any way I can remove this Alarm, I dont want to reboot ASR and I already run clear facility-Alarm command. The output displays the following information: Column. For the latest feature information and caveats, see the release notes for your platform and software release. The example shows a critical alarm for Power supply along with the. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Source-----subslot 0/0. The example shows a critical alarm for Power supply along with the description: Router# show facility-alarm status System Totals Critical: 2 Major: 0 Minor: 1Port Status Monitoring Alarms. Sends power supply alarm traps to a syslog server. Verifying Normal Startup Sequence. show cable calls. Hello, I have a Cisco ASR 1006-X that I cant seem to get the crit led light to go off, I have been under the impression that interfaces that are down, down vs being admin down would cause this but all my interfaces are up, up or admin down. Source-----subslot 0/0. show alarm settings. show alarm. Depending on the type of alarms you configure, you might see. show facility-alarm status [critical | info | major] Displays generated alarms on. Displays all global alarm settings on the switch. show env power. f985. show alarm settings. Step 8. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. > show facility-alarm status info Source Severity Description Relay Time firepower minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 firepower minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 firepower major Redundant pwr missing or failed. Clearing Specific Alarms and EventsFacility Protocol Status Support; Monitoring Alarms. MIBs. Is it possible to disable the critical facility-alarm for the 'interface link-down' status, so the 'stat' led on the device doesn't turn red? (the interface is intended to be no shut, but normally down) #show facility-alarm status System Totals Critical: 1 Major: 0 Minor: 0 Source. Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index] ----- ----- ----- ----- TenGigabitEthernet0/0/0 May 18 2016 14:53:02 CRITICAL Physical Port Link Down [35] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1] GigabitEthernet0/1/1 May 11 2016 18:53:. To view alarms, use the show facility-alarm status command. show facility-alarm status. The example shows a critical alarm for Power supply along with the description: SPA Removed. show facility-alarm relay. •show facility-alarm status [info |major |minor] AlarmsfortheCiscoISA3000 6 AlarmsfortheCiscoISA3000 MonitoringAlarms. However, this command does not fix the alarm condition that triggered the external alarm: you still must resolve the problem. show facility-alarm relay. The clear facility-alarm command does not clear an alarm LED on the Cisco Catalyst 9800-40 Wireless Controller. Verifies the configuration. To view alarms, use the show facility-alarm status command. Shows information about the physical status of the input alarm contacts. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. 1g and 16. Return to privileged EXEC mode. The LEDs indicate all system states in the startup sequence. Displays all global alarm settings on the switch. alarm facility power-supply relay major. showf~showipu •showfacility-alarm(3ページ) •showfailover(6ページ) •showfailoverdescriptor(21ページ) •showfailoverexec(22ページ)Router(config)# logging alarm critical. Effective from Cisco IOS XE Everest 16. For the latest feature information and caveats, see the release notes for your platform and software release. Displays the switch power status. Switch#show facility-alarm status Source Severity Description Relay Time Switch MINOR 34 HSR ring is partially down MAJ Oct 24 2017 10:16:10 ----- Switch# show facility-alarm status Source Severity Description. The router configures, manages, and controls the supported Cisco Enhanced Services Modules (SMs) and Network Interface Modules (NIMs) using the module management facility built in its architecture. Shows the current configuration for each possible alarm. Step 4 show facility-alarm status Example: Router(config)# show facility-alarm status Generates output that shows information about each alarm depending on the severity level that is set. To view the alarms on Cisco ASR 1001 router, use the show facility-alarm status command. Monitoring Syslog Messages for Alarms. Options. Router# show facility-alarm status critical System Totals Critical: 5 Major: 0 Minor: 0 Source Severity Description [Index] ----- ----- ----- Power Supply Bay 0 CRITICAL Power Supply/FAN Module Missing [0] GigabitEthernet0/0/0 INFO Physical Port Link Down [1] GigabitEthernet0/0/1 INFO Physical Port Link Down [1] GigabitEthernet0/0/2 INFO. Configuration Examples for Switch Alarms Associating Temperature Alarms to a Relay: Examples . For the latest feature information and caveats, see the release notes for your platform and software release. For the latest feature information and caveats, see the release notes for your platform and software release. alarm facility power-supply syslog. Alarm Output Interface. Documentation would suggest Alarm led sould be stdy green. show env {all | power | temperature} Displays the status of environmental facilities on the switch. Insteadofconfiguringonecontact,youcanspecifyanytochangetheseverityforallcontacts. Output looks like this: asr1001#show facility-alerm status System Totals Critical: 2. Facility Protocol Status Support Monitoring Alarms Once hardware is installed and operational, use alarms to monitor hardware status on a daily basis. Device from which the alarm was triggered. Verifying Normal Startup Sequence. Shows the current configuration for each possible alarm. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. The table below captures some of the key hardware capabilities of this new platforms. 10. Shows information about the alarms that have triggered the output relay. Device from which the alarm was triggered. Router# show facility-alarm status System Totals Critical: 22 Major: 0 Minor: 0 Source Time Severity Description [Index]----- ----- ----- -----subslot 0/0 May 18 2016 14:50:49 CRITICAL Active Card Removed OIR Alarm [0] GigabitEthernet0/1/0 May 11 2016 18:53:36 CRITICAL Physical Port Link Down [1]. show cable licenses all. Verifies the configuration. AlarmConfiguringandMonitoringGuide,CiscoIOSXE17(ASR920 SeriesRouters) FirstPublished:2020-07-31 LastModified:2023-03-23 AmericasHeadquarters CiscoSystems,Inc. Source Severity Description Relay Time. System alarms are displayed first followed by the system events. show alarm settings Verifies the configuration. show alarm-profile name —Displays the alarm profile configured for chassis. Shows information about the physical status of the input alarm contacts. SNMP traps are generated when the inlet temperature sensor of the Cisco UBR-MC20X20V cable interface line card has a status change among normal, minor, major or critical. In the event of a Fan failure, the Fan tray status will be displayed as "fail" along with the details of the individual€units which has failed. Insteadofconfiguringonecontact,youcanspecifyanytochangetheseverityforallcontacts. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. The LEDs indicate all system states in the startup sequence. Examples of Alarm Messages. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. Examples of Alarm Messages. #show facility-alarms status. show env {all | power | temperature} Displays the status of environmental facilities on the switch. You can limit the view by filtering on major or minor status. Step 9. Displays the switch power status. The LEDs indicate all system states in the startup sequence. For example, if a. Use the show facility-alarm status command to display more information about the alarm condition. You can limit the view by filtering on major or minor status. The info keyword provides the same output as using no keyword. By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the “Feature Information for Alarm and Event Management” section. To view alarms, use the show facility-alarm status command. show facility-alarm status [critical | info | major] Displays generated alarms on. show environment alarm-contact. For the latest feature information and caveats, see the release notes for your platform and software release. alarm facility power-supply syslog. The info keyword provides the same output as using no keyword. The alarm output interface functions as a relay and also has a corresponding LED, which conveys the alarm status of an external sensor connected to the input interface, and internal sensors such as the dual power supply and temperature sensors. The alarm status is polled every second to check if there are any changes in the alarm state (based on the user configuration). By checking the state of the LEDs, you can determine when and where the system failed in the startup sequence. ciscoasa> show facility-alarm status info Source Severity Description Relay Time ciscoasa minor external alarm contact 1 triggered Energized 06:56:50 UTC Mon Sep 22 2014 ciscoasa minor Temp below Secondary Threshold De-energized 06:56:49 UTC Mon Sep 22 2014 ciscoasa major Redundant pwr missing or failed De-energized 07:00:19 UTC Mon Sep 22 2014. Verifying Normal Startup Sequence. Sends power supply alarm traps to a syslog server. show environment alarm-contact. However, network administrators can perform onsite. Shows facility alarms by status and displays the settings of all user-configurable alarm thresholds. alarm facility power-supply syslog. Examples of Alarm Messages. Return to privileged EXEC mode. Voltage Fornormaloperation,onlyonepowerfeed(A900-PWR900-D2)issufficientbutanalarmisgeneratedifonly onepowerfeedispresent. 11. SNMP Traps. Depending on the type of alarms you configure, you might see. 1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. Alarms. Use the show platform and show environment all commands to check the online and environmental status of each FRU after installation. Tologthealarms,youneedtoenabletheloggingalarm[critical|major|minor|informational]command attheglobalconfigurationmode. The following example de-energizes the output relay and clears the alarm state of the output LED: > clear facility. For the latest feature information and caveats, see the release notes for your platform and software release. Command Purpose Step 1 configure terminal Enters global configuration mode. All 9800 appliances (9800-L, 9800-40 and 9800-80) have an ALM LED on their front panel. On the ASR 1000 chassis that uses the affected Cisco IOS XE images (see the Products Affected section), the PSU state might be incorrectly displayed as “ps fail” even though the PSU functions as intended. To view alarms, use the show facility-alarm status command. Network administrators do not need to use show commands to poll devices on a routine basis and can monitor the network remotely. To display the alarm status attached to a specfic profile, use the show facility-alarm status command: Router# show facility-alarm status | inc 0/4/40 T3 0/4/40 Feb 01 2018 19:23:10 MAJOR Section Receiver has loss of signal [1] Verifying Alarm Profile for Severity Change for T3 or E3 Alarms To view the alarms on Cisco ASR 1001 router, use the show facility-alarm status command. Bias-Free Language. Shows information about the physical status of the input alarm contacts. If alarm severity is not specified, alarm messages for all severity levels are sent to logging devices. Shows the current configuration for each possible alarm. configure terminal Enters global configuration mode. BB ** How to Ask The Cisco Community for Help. Examples of Alarm Messages. configure terminal Enters global configuration mode. To view the posted temperature sensor alarms, use the show facility-alarm status command to show all the alarms in the system. Command Purpose Step 1 configure terminal Enters global configuration mode.